Ang LX13xxCDR SFP transceivers, ayon sa SFP Multi-Sourcing Agreement (MSA) SFF-8074i at DWDM SFP MSA rebisyon 1.0, ay idinisenyo para sa Gigabit Ethernet Dense Wavelength Division Multiplexing (DWDM) na mga sistema sa networking. Ang mga operating wavelength nito ay maaaring sumakop sa C-band at L-band. Ang LX13xxCDR ay mayroong pinahusay na Digital Diagnostic Monitoring (DDM) na tungkulin.
Ang LX13xxCDR SFP transceivers, ayon sa SFP Multi-Sourcing Agreement (MSA) SFF-8074i at DWDM SFP MSA rebisyon 1.0, ay idinisenyo para sa Gigabit Ethernet Dense Wavelength Division Multiplexing (DWDM) na mga sistema sa networking. Ang mga operasyonal na wavelength ay maaaring saklaw ang C-band at L-band.
Ang LX13xxCDR ay may tampok na pinalakas na Digital Diagnostic Monitoring (DDM) na punsyon.
Mga teknikal na detalye ayon sa DWDM SFP MSA, rebisyon 1.0
Magagamit ang pinalakas na digital diagnostic monitoring
DWDM na may 100GHz ITU grid
Sakop ang C-band at L-band
Hanggang 1.25Gb/s na bi-directional na data link
Duplex LC connector na sumusunod sa standard
Solong +3.3V DC power supply
Hot-pluggable SFP footprint
Sertipikado sa kaligtasan ng laser na Class 1
Pagpapatakbo ng temperatura na Opsyon (Komersyal) -10℃ hanggang +70℃
Hanggang 120km (2400ps/nm) na paghahatid
Optical Characteristics
Talahanayan 1. Mga Optikal na Katangian ng Tagapaghatid
|
Parameter |
Simbolo |
Pinakamaliit |
Karaniwan |
Maximum |
Yunit |
Mga Tala |
|
Lakas ng Optikal na Paglulunsad |
Po |
+0 |
- |
+5 |
dBm |
- |
|
Espasyo ng Gitnang Haba ng Alon |
- |
- |
100 |
- |
GHz |
- |
|
Katatagan ng Haba ng Alon |
δλc |
-0.1 |
+0.1 |
nm |
- |
|
|
Extinction Ratio |
Ex |
9.0 |
- |
- |
dB |
- |
|
Lapad ng Espektral (-20dB) |
δλ |
- |
- |
0.3 |
nm |
- |
|
Side Mode Suppression Ratio |
SMSR |
30 |
- |
- |
dB |
- |
|
Kabuuang Jitter |
Tj |
- |
- |
0.075 |
Ugnay |
- |
|
Parusa sa Dispersion |
- |
- |
- |
3 |
dB |
- |
|
Optical Rise/Fall Time |
Trise/Tfall< |
- |
- |
260 |
ps |
- |
|
Pout @TX-Disable Naipasa |
Poff |
- |
- |
-40 |
dBm |
- |
|
Larawan ng Mata |
IEEE Std 802.3-2005 Gigabit Ethernet 1000BASE na tugma |
|||||
Talahanayan 2. Mga Katangian ng Optikal na Tatanggap
|
Parameter |
Simbolo |
Pinakamaliit |
Karaniwan |
Maximum |
Yunit |
Mga Tala |
|
Sensitibo ng tumatanggap |
S |
- |
- |
-32 |
dBm |
1 |
|
Sobrang Presyo ng Tagatanggap |
POL |
-7 |
- |
- |
dBm |
1 |
|
Optical return loss |
ORL |
27 |
- |
- |
dB |
|
|
LOS De-Ipaglaban |
LOSD |
- |
- |
-33 |
dBm |
- |
|
LOS Assert |
LOSA |
-45 |
- |
- |
dBm |
- |
|
LOS Hysteresis |
- |
0.5 |
3 |
5 |
dB |
- |
Tandaan:
1. Sinukat gamit ang PRBS 27-1 test pattern, 1.25Gb/s, EX=9dB, BER<10-12.
Impormasyon sa Pag-order
Talahanayan 1. Impormasyon sa Pag-order
|
Numero ng Bahagi |
Transmitter |
Output na Lakas |
Tumatanggap |
Sensitivity |
Maabot |
TEMP |
DDM |
ROHS |
|
LX13xxCDR |
DWDM DFB |
0 ~ +5dBm |
APD |
< -32dBm |
120KM |
-10 ~ 70℃ |
Magagamit |
Nakikilala |
Tandaan: Tingnan ang Talahanayan 2 – Gabay sa Habang ng Daluyong para sa halaga ng "xx".
Talahanayan 2. Gabay sa Habang ng Daluyong para sa halaga ng "xx" (kanal na 100GHz ITU-T)
|
Bilang ng Kanal |
Numero ng Bahagi ng Produkto |
Dalas (THz) |
Sentro ng panlang (nm) |
|
66 |
LX1366CDR |
186.6 |
1606.60 |
|
67 |
LX1367CDR |
186.7 |
1605.74 |
|
68 |
LX1368CDR |
186.8 |
1604.88 |
|
69 |
LX1369CDR |
186.9 |
1604.03 |
|
70 |
LX1370CDR |
187.0 |
1603.17 |
|
71 |
LX1371CDR |
187.1 |
1602.31 |
|
72 |
LX1372CDR |
187.2 |
1601.46 |
|
73 |
LX1373CDR |
187.3 |
1600.60 |
|
74 |
LX1374CDR |
187.4 |
1599.75 |
|
75 |
LX1375CDR |
187.5 |
1598.89 |
|
76 |
LX1376CDR |
187.6 |
1598.04 |
|
77 |
LX1377CDR |
187.7 |
1597.19 |
|
78 |
LX1378CDR |
187.8 |
1596.34 |
|
79 |
LX1379CDR |
187.9 |
1595.49 |
|
80 |
LX1380CDR |
188.0 |
1594.64 |
|
81 |
LX1381CDR |
188.1 |
1593.79 |
|
82 |
LX1382CDR |
188.2 |
1592.95 |
|
83 |
LX1383CDR |
188.3 |
1592.10 |
|
84 |
LX1384CDR |
188.4 |
1591.26 |
|
85 |
LX1385CDR |
188.5 |
1590.41 |
|
86 |
LX1386CDR |
188.6 |
1589.57 |
|
87 |
LX1387CDR |
188.7 |
1588.73 |
|
88 |
LX1388CDR |
188.8 |
1587.88 |
|
89 |
LX1389CDR |
188.9 |
1587.04 |
|
90 |
LX1390CDR |
189.0 |
1586.20 |
|
91 |
LX1391CDR |
189.1 |
1585.36 |
|
92 |
LX1392CDR |
189.2 |
1584.53 |
|
93 |
LX1393CDR |
189.3 |
1583.69 |
|
94 |
LX1394CDR |
189.4 |
1582.85 |
|
95 |
LX1395CDR |
189.5 |
1582.02 |
|
96 |
LX1396CDR |
189.6 |
1581.18 |
|
97 |
LX1397CDR |
189.7 |
1580.35 |
|
98 |
LX1398CDR |
189.8 |
1579.52 |
|
99 |
LX1399CDR |
189.9 |
1578.69 |
|
00 |
LX1300CDR |
190.0 |
1577.86 |
|
01 |
LX1301CDR |
190.1 |
1577.03 |
|
02 |
LX1302CDR |
190.2 |
1576.20 |
|
03 |
LX1303CDR |
190.3 |
1575.37 |
|
04 |
LX1304CDR |
190.4 |
1574.54 |
|
05 |
LX1305CDR |
190.5 |
1573.71 |
|
06 |
LX1306CDR |
190.6 |
1572.89 |
|
07 |
LX1307CDR |
190.7 |
1572.06 |
|
08 |
LX1308CDR |
190.8 |
1571.24 |
|
09 |
LX1309CDR |
190.9 |
1570.42 |
|
10 |
LX1310CDR |
191.0 |
1569.59 |
|
11 |
LX1311CDR |
191.1 |
1568.77 |
|
12 |
LX1312CDR |
191.2 |
1567.95 |
|
13 |
LX1313CDR |
191.3 |
1567.13 |
|
14 |
LX1314CDR |
191.4 |
1566.31 |
|
15 |
LX1315CDR |
191.5 |
1565.50 |
|
16 |
LX1316CDR |
191.6 |
1564.68 |
|
17 |
LX1317CDR |
191.7 |
1563.86 |
|
18 |
LX1318CDR |
191.8 |
1563.05 |
|
19 |
LX1319CDR |
191.9 |
1562.23 |
|
20 |
LX1320CDR |
192.0 |
1561.42 |
|
21 |
LX1321CDR |
192.1 |
1560.61 |
|
22 |
LX1322CDR |
192.2 |
1559.79 |
|
23 |
LX1323CDR |
192.3 |
1558.98 |
|
24 |
LX1324CDR |
192.4 |
1558.17 |
|
25 |
LX1325CDR |
192.5 |
1557.36 |
|
26 |
LX1326CDR |
192.6 |
1556.55 |
|
27 |
LX1327CDR |
192.7 |
1555.75 |
|
28 |
LX1328CDR |
192.8 |
1554.94 |
|
29 |
LX1329CDR |
192.9 |
1554.13 |
|
30 |
LX1330CDR |
193.0 |
1553.33 |
|
31 |
LX1331CDR |
193.1 |
1552.52 |
|
32 |
LX1332CDR |
193.2 |
1551.72 |
|
33 |
LX1333CDR |
193.3 |
1550.92 |
|
34 |
LX1334CDR |
193.4 |
1550.12 |
|
35 |
LX1335CDR |
193.5 |
1549.32 |
|
36 |
LX1336CDR |
193.6 |
1548.51 |
|
37 |
LX1337CDR |
193.7 |
1547.72 |
|
38 |
LX1338CDR |
193.8 |
1546.92 |
|
39 |
LX1339CDR |
193.9 |
1546.12 |
|
40 |
LX1340CDR |
194.0 |
1545.32 |
|
41 |
LX1341CDR |
194.1 |
1544.53 |
|
42 |
LX1342CDR |
194.2 |
1543.73 |
|
43 |
LX1343CDR |
194.3 |
1542.94 |
|
44 |
LX1344CDR |
194.4 |
1542.14 |
|
45 |
LX1345CDR |
194.5 |
1541.35 |
|
46 |
LX1346CDR |
194.6 |
1540.56 |
|
47 |
LX1347CDR |
194.7 |
1539.77 |
|
48 |
LX1348CDR |
194.8 |
1538.98 |
|
49 |
LX1349CDR |
194.9 |
1538.19 |
|
50 |
LX1350CDR |
195.0 |
1537.40 |
|
51 |
LX1351CDR |
195.1 |
1536.61 |
|
52 |
LX1352CDR |
195.2 |
1535.82 |
|
53 |
LX1353CDR |
195.3 |
1535.04 |
|
54 |
LX1354CDR |
195.4 |
1534.25 |
|
55 |
LX1355CDR |
195.5 |
1533.47 |
|
56 |
LX1356CDR |
195.6 |
1532.68 |
|
57 |
LX1357CDR |
195.7 |
1531.90 |
|
58 |
LX1358CDR |
195.8 |
1531.12 |
|
59 |
LX1359CDR |
195.9 |
1530.33 |
|
60 |
LX1360CDR |
196.0 |
1529.55 |
|
61 |
LX1361CDR |
196.1 |
1528.77 |
Pinatinding mga network ng DWDM
Ethernet sa WDM
Fiber Channel sa WDM